The DigiSpec® series of imaging spectrophotometers is a game-changer for color measurement, and you can use it for pretty much any color measuring task.
DigiSpec® can grab color and spectral data for every single point in an image, and it can measure areas as tiny as 0.0016mm² (0.04mm*0.04mm).
Its measurement repeatability is dEab ≤ 0.01, whether you're checking a white or black standard plate, setting a new bar for desktop spectrophotometers.
With a solid calibration setup and smart algorithms, you get super reliable short-term and long-term stability.
The LED light source keeps data consistent with the previous generation of traditional spectrophotometers.
There are 20+ standard light sources, 30+ measurement indicators, and SCI/SCE measurement conditions, covering all the functions of the older spectrophotometers and giving you the same measurement parameters and conditions.

| Model | DS‑1000 | DS‑1050 | DS‑1100 |
| Instrument Type | Dual‑beam d/8° Spectro‑analyzer, SCI (including specular reflection) / SCE (excluding specular reflection) | ||
| Light Source | Full‑spectrum LED | High‑precision simulated daylight full‑spectrum LED | |
| Integrating Sphere Diameter | 152mm / 6in | ||
| Wavelength Range | 400nm‑700nm (Covers full visible range) | 400nm‑1000nm (Covers near‑infrared and full visible range) | |
| Spectral Resolution | 10nm | ||
| Photometric Range | 0‑200%, Resolution: 0.01% | ||
| Repeatability (30 measurements of white standard, CIE LAB) | ΔE*abs≤0.03 | ΔE*abs≤0.01 | |
| Instrument‑to‑Instrument Agreement (Reflectance Test, CIE LAB) | 0.4 | 0.25 | |
| Measuring Aperture | 25×25mm | ||
| Image Resolution | ≥300×300 pixels | ≥600×600 pixels | |
| Aperture Plate | LAV (30mm illumination, 25mm measurement). User‑defined measurement area; custom‑size aperture available | ||
| Measurement Conditions | Compliance Standards: CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, DIN5033 Teil7, JIS Z8722 Condition C, ASTM E1164, ASTM‑D1003‑07 | ||
| Sensor | CMOS Array Sensor | Silicon Metal‑Oxide Image Sensor | |
| Spectroscopic Method | Grating | Ultra‑precision Holographic Transmission Grating | |
| Spatial Resolution | 300dpi | 500dpi (High Resolution) | 600dpi (Ultra‑high Resolution) |
| Minimum Measuring Area | Better than 0.01mm² (0.1×0.1mm) | Better than 0.004mm² (0.06×0.06mm) | Better than 0.0016mm² (0.04×0.04mm) |
| Standard Observer | 2° Standard Observer & 10° Standard Observer | ||
| Observation Illuminant | A, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, U30, DLF, NBF, TL83, TL84 | ||
| Color Space | Lab, Lch, Hunter Lab, Yxy, XYZ | ||
| Color Indices | WI(ASTM E313‑00, ASTM E313‑73, CIE, ISO2470/R457, AATCC, Hunter, Taube, Berger Stensby), YI(ASTM D1925, ASTM E313‑73), Tint(ASTM E313‑00), Metamerism Index MlM, Staining Fastness, Variable Color Fastness, ISO Brightness, R457 Density, T Density, E Density, M Density, Hiding Power, Tint, Strength | ||
| Color Difference Formula | ΔEab, ΔECH, ΔEuv, ΔEcmc, ΔE94, ΔE00, ΔEab(Hunter), 555 Color Classification | ||
| Measurement Time | Less than 8s | Less than 5s | |
| Operating Temperature & Humidity | 5 ~ 40°C, Relative Humidity 80% (no condensation below 35°C) | ||
| Storage Temperature & Humidity | -20 ~ 45°C, Relative Humidity 80% (no condensation below 35°C) | ||
| Accessories | Power adapter, Data cable, White calibration plate | ||
| Interface | USB 3.0 | ||
*The color of different material surfaces is greatly affected by temperature. ΔEabs 0.01 represents extremely high measurement stability. When testing the repeatability of DigiSpec®, please ensure the surface stability of the tested object. After instrument calibration, perform 30 measurements on the BCRA white tile at an interval of 10 seconds, using a 25×25mm aperture to calculate the standard deviation of the results.
** Average value of measurement results on 12 BCRA ceramic standard plates.